Smart Sensor AS218 Digital PH Tester Meter with Range 0.00~14.00pH
1. All products with original packaging box, so that can protect the products well on the shipping way avoid damage.
2. The product contain the battery because of the limitation of the airline company.
3. Warranty: All units are with Retail box. and we offer Long warranty period of 2 years,in two years will repair for free.
4. Shipping Way: if you need it faster, you can choose ÇØ¿Ü standard shipping,also have China post airmail !
A pH meter is an electronic device used for measuring the pH which is either the concentration of Hydrogen ions in an aqueous solution or the activity of the Hydrogen ions in an aqueous solution. The pH will indicate if the solution is acidic or basic, but is not a measure of acidity or alkalinity. pH meters work in liquids though special probes are sometimes used to measure the pH of semi-solid substances. A pH meter consists of a special measuring probe (a glass electrode) connected to the body which measures and displays the pH reading.
1. Data hold, Max & Min measurement function.
2. Separated pH and temperature sensor probes pH meter: It is easy to carry.
3. Low battery indication and 30 minutes auto power off:It can remind you and save the power.
4. LCD display and Backlight: It is easy to read and accurately testing.
5. Apply in water sources, aquarium, hydroponics, spas, swimming pools and other water systems.
6. Electrode probe can be replaced - Replaceable BNC pH sensor probe.
Product Specification
|
Instrument Level:
|
|
Grade 0.01
|
PH Measuring range:
|
PH 0.00~14.00pH
|
PH basic measurement error:
|
¡¾ 0.05pH
|
Instrument Repeatability:
|
¡¾0.03pH
|
Solution temperature compensation range:
|
0 ~ 60¡ÆC
|
instrument repeatability
|
0.03pH
|
mV measuring range:
|
-1400mV¡¾1400mV
|
temperature range:
|
-10 ~ 60 ; 0.1¡ÆC
|
Battery:
|
9V Battery (not include)
|
Display:
|
Large LCD segment type display with back light
|
Working temperature:
|
0 ~ 35¡ÆC
|
Working humidity:
|
0-80% R H ( Non Gel)
|
Product Net Weight
|
205g
|
Product Size
|
159*66*31mm
|
Packing contents
|
1. AS218 type electronic unit 1 pc;
2. Ph composite electrode:general purpose and field usage.
12.3mm diia.X 160mm.plastic body*1pcs
3. PH4.00, PH6.86, PH9.18 calibration power*2 bags ench type(see picture)
4. electrode liquid storage bottle:*1pc
5. instruction manual and warranty card:one set each
|
Normal Condition of Use
|
(1)
|
|
the environment temperature (0 ~ 35) ;
|
(2)
|
the relative humidity is not more than 80%;
|
(3)
|
measured solution temperature: (5 ~ 60 );
|
(4)
|
power supply: 9V DC battery X 1pc (006P);
|
(5)
|
no significant vibration;
|
(6)
|
in addition to the earth`s magnetic field without external magnetic field outside interference.
|
Open the battery door that located at the back of theinstrument, insert a new 9V battery into this compartmentwith correct polarity. If you have replaced with a new PHcompositeelectrode, please do the calibration before usethis unit to measure.
If measuring interval time is short, one month calibrationonce is enough.
This instruction use three point calibration method foralibrate this unit, please following the step one by one
The unit and calibration solution must be calibrated atambient environment temperature 25 C +/-2 C.
User`s Guide
|
¨ç
|
Press "MODE" key go to three different calibrationmode [CAL 1], [CAL 2] and [CAL 3].
|
¨è
|
according to the "mode" button instrument into the correction state, respectively into "C4.0" "C6.86" "C9.18" three states cycle scintillation indicating symbol.
|
¨é
|
Correction steps are as follows:
A: PH4.00 buffer solution calibration: Press "MODE" key go to [CAL 1] icon shown and flashing, rinse the PH electrode with distilled water, immerse the electrode in the PH4.00 buffer solution, wait for the electrode become stable, you should find the value of mV don`t change and state at same value, this time press [CAL ] key more than 3 seconds. until [4.00] flashing stop and disappeared, so the PH4.00 calibration completed.
B: PH6.86 buffer solution calibration: Press "MODE" key two times go to [CAL 2] icon shown and flashing, rinse the PH electrode with distilled water, immerse the electrode in the PH6.86 buffer solution, wait for the electrode become stable, you should find the value of mV don`t change and state at same value, this time press[CAL ] key more than 3 seconds.until [6.86] flashing stop and disappeared, so the PH6.86 calibration completed
C: PH9.18 buffer solution calibration: Press "MODE" key three times go to [CAL 3] icon shown and flashing, rinse the PH electrode with distilled water, immerse the electrode in the PH9.18 buffer solution, wait for the electrode become stable, you should find the value of mV don`t change and state at same value, this time press[CAL ] key more than 3 seconds.until [9.18] flashing stop and disappeared, so the PH9.18 calibration completed.
|
¨ê
|
normal measurement mode: The factory default mode is normal measuring mode if you press [ the power on/off ] button to turn it on. At this normal measure mode, the unit can measure the PH and environment temperature at the same time, just immerse the electrode into the solution that you want to measure the PH value
mV measure mode:Press `MODE" key four times go to mV measure mode,which enable you to measure the ion ?selective, ORP(oxidation-reduction potential) and other precise mV measurements. At that mode LCD display screen show mV and ambient temperature at the same time.
|
¨ë
|
If the battery power indicator icon become empty,please replace a new 9V battery immediately, If the instrument will not be use in a long period, please take out the battery from the battery compartment to prevent any leakage of the battery to damage the instrument.
|
In the following circumstances, Instruments Must be to correction:
|
¨ç
|
The solution temperature have a large difference with the calibrated temperature
|
¨è
|
PH electrode took off from the liquid storage bottle too long time.
|
¨é
|
Replaced with a new PH electrode
|
¨ê
|
After measured at high concentration acid (PH<2) or alkali (PH>12) solution
|
¨ë
|
After measured fluoride solution and acidity within PH<7 or concentrated organic solution
|
¨ì
|
When calibrate, please make sure the buffer solution temperature must be 25¡ÆC¡¾ 2¡ÆC
|
1) We accept Alipay, West Union, TT. All major credit cards are accepted through secure payment processor ESCROW.
2) Payment must be made within 3 days of order.
3) If you can`t checkout immediately after auction close, please wait for a few minutes and retry Payments must be completed within 3 days.
1. WORLDWIDE SHIPPING. (Except some countries and APO/FPO)
2. Orders processed timely after the payment verification.
3. We only ship to confirmed order addresses. Your order address MUST MATCH your Shipping address.
4. The images shown are not the actual item and are for your reference only.
5. SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season.
6. If you have not received your shipment within 30 days from payment, please contact us. We will track the shipment and get back to you as soon as possible with a reply. Our goal is customer satisfaction!
7. Due to stock status and time differences, we will choose to ship your item from our first available warehouse for fast delivery.
1. You have 7 days to contact us and 30 days to return it from the date it was received. If this item is in your possession more than 7 days, it is considered used and WE WILL NOT ISSUE YOU A REFUND OR REPLACEMENT. There are NO EXCEPTIONS! Shipping cost is bear by both seller and buyer in half.
2. All returned items MUST BE in the original packaging and you MUST PROVIDE us with the shipping tracking number, specific reason for the return, and your po#.
3. We will refund YOUR FULL WINNING BID AMOUNT, upon receipt of the item in its original condition and packaging with all components and accessories included, AFTER BOTH Buyer and Seller cancel the transaction from ÇØ¿Ü. OR, you may choose to have a replacement.
4. We will bear all the shipping cost if the product(s) is (are) not as advertised.
1. 24 months Manufacturer`s limited Warranty for defective items (excluding items damaged and/or misused after receipt). Accessories come with a 3-month warranty.
2. Defective items MUST BE reported and returned within the warranty period (and in the original packaging, if possible). You must tell us what the defect is and give us your order number. WE DO NOT REPAIR OR REPLACE ITEMS WITH AN EXPIRED WARRANTY.
You agree to all of the above-listed policies upon ordering on ÇØ¿Ü!
We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important We request that you contact us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.
It is impossible to address issues if we do not know about them!