|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- Ä¿Çøµ À¯Çü: join
- ¸ðµ¨ ¹øÈ£: TUF-2000M
- DIY ¿ëÇ°: ¹è°ü
- ºê·£µå À̸§: Barry Century
- ±Ù¿ø: CN (Á¤Ç°)
¿É¼ÇÁ¤º¸[(366)HOST WITH TS-2][(496)HOST WITH TM-1][(865)HOST WITH TL-1][(200021498)DN15-100mm Sensor][(203196826)DN50-700mm Sensor][(193)HOST ONLY][(175)HOST WITH TC-1]
TUF-2000M-TM-1 DN50-700mm Flow Module for Digital Ultrasonic Flowmeter Flow Meter Sensor Indicator Counter MainFeatures:
Features |
Description |
High accuracy |
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1% |
Wide measuring range |
Several types transducer for selection, pipe size from DN15mm to DN6000mm |
Far transmission distance |
Connecting module and secondary meter through RS-485 interface, transmission distance up to 1000m |
Powerful Functions |
Current output: 4-20mA, one channel, can be used for flow/heat transmitter; OCT output: two channels, can be used for flow /heat switch; Current input: 4-20mA, three channels, can be used for data collector; Tri-wire resistance signal input (PT100): two channels, can be used for calorimeter. |
Wide Application |
Its unique features, particularly low cost, small size, high performance, local display, make it the ideal choice for industrial automation, processing control, flow meter networking, composing multi-channel, high accuracy flow meter. |
Notice:If you need the modules to measure heat, please indicate when place an order.
General Specification |
General Specification: |
|
Optional Transduers |
Model |
Measuring Range |
Liquid Temperature |
Accuracy |
Clamp-on |
TS-2(small size) |
TUF-2000MNB1 |
DN15-100mm |
-30C°¡90C° |
Flow±1% Heat±2% |
|
TM-1(medium size) |
TUF-2000MNB2 |
DN50-700mm |
TL-1(large size) |
TUF-2000MNB3 |
DN300-6000mm |
High-tem clamp-on |
THS-1(small size) |
TUF-2000MNB4 |
DN15-100mm |
-30C°¡160C° |
|
THM-1(medium size) |
TUF-2000MNB5 |
DN50-700mm |
Insertion |
TC-1(standard) |
TUF-2000MNC1 |
DN80-6000mm |
-40C°¡160C° |
|
TLC-2(lengthen) |
TUF-2000MNC2 |
Prover Section |
Prover Section |
TUF-2000MNG |
DN15-1000mm (see appendix 2) |
-40C°¡160C° |
Flow±0.5% |
|
Power Supply |
Primary meter: 8-36VDC , Secondary meter: AC220V or DC24V |
Input |
3 channel 4-20mA analog input, 2 channel Tri-wire resistance signal input (PT100) |
Output |
Isolation RS-232/RS-485 output, 2 channel isolation OCT output 1 channel isolation 4-20mA output (two-wire system) |
Communication Protocols |
Compatible with MODBUS, METER-BUS protocol, Fuji extended protocol and general water meter protocol. |
|
Structure of Unified Calorimeter |
|
|
composition diagram of flow Point-measuring |
|
|
|
|
|