Voltage: 220V-240V;50~60Hz
Current Load: 16A
Power consuption: 0.3W
Setting range: 5-99 Celsius
Floor Setting Range: 5-99 Celsius
Accuracy: ±0.5 Celsius
Installation Box: 80*80mm
Manual download
Our Advantage
1. External Floor Sensor
We use the different sensor, our sensor is more stable, it can accurately detect your floor temperature, so it can provide a precise temperature for thermostat controlling;
2. Professional Designer & Manufacturer
We are professional designer and manufacturer in the field of HVAC.
By adhering to the corporate spirit of "quality first, customer uppermost" and based on professional technology and reliable after-sales service, our company has been warmly accepted by customers.
Wiring Diagram
Terminal 1(L1) and 2(N1) are electric loading appliances controlled by thermostat.
Terminal 3(N) and 4(L) are AC230V power supply of the thermostat.
Terminal 5 and 6 (NTC) are external temperature sensor.
FAQ (Frequently Asked Question)
1. What`s the difference between TGT70-EP and TGT70-WP thermostat?
TGT70-EP Thermostat is used in 16A Electric Underfloor Heating System. It is used to control heating cables, heating films or heating mats;
TGT70-EP thermostat is with Two Sensors( internal sensor and a external sensor );
TGT70-WP Thermostat is used in 3A Water Underfloor Heating System. It is used to control water valves or electric thermal actuators.
TGT70-WP Thermostat is with only one Internal sensor;
2. TGT70-EP is suitable for electric heating system?
Yes!
3. TGT70-EP is with an external floor sensor?
Yes! The external floor sensor is 3m length.
4. TGT70-EP is suitable for gas boiler?
TGT70-EP thermostat is used in electric underfloor heating system, not for a gas boiler. If you want to control gas boiler, please contact with the seller to check our BOT-X306 Wireless Boiler Thermostat.
5. I have a heating appliance, is your TGT70-EP thermostat suitable to control it?
You can contact us on AliExpress to consult it. Please also provide your heating appliance photo, especially the connection wires photo.
6. Is this thermostat programmable?
Our TGT70 Series thermostat is programmable thermostat. You can choose 5+2 weekly programmable, 5+1+1 weekly programmable, or 7 days programmable. The minimum unit of programmable time is 1 mitute. ( For example, you can set the time of Period1 to be any time from 6:01 to 6:59.
7. How to check floor temperature?
During power on, press and hold then press the button of power to check floor temperature, OUT TEMP will display.
Press again to display room temperature.
Main Function Operation
1. Setting the Power ON/OFF
Press to turn on/off the power.
2.Setting Temperature
Press to set the temperature.
3. Setting the Clock
Press to set the minute, hour and week.
Press to adjust.
4. Setting the Manual Mode
Manual mode means non-programmable mode.
Press , then will display on the screen, it is in manual mode.
Press to set the temperature.
Press to set minute, hour and week.
5. Setting the Children Lock
Long Press to enter into child lock mode, will display.
Long press again, the child lock will be disappeared.
6. Setting the Programmable Mode
Press and hold into programmable mode. LOOP and 12345 will display.
Press to select the control way:5+2/6+1/7 days programmable.
12345 display in the position of week means 5+2;
123456 display in the position of week means 6+1;
1234567 display in the position of week means 7 days programmable.
Press to select the periods.
Press to change the temperature.
Press to select the time adjustment.
Press to adjust the time.
Press again to select the weekend`s temperature.
If you want to make temperatory adjustment in any period, press then
will flash. When finish the setting, all will automatically confirm.
Press to switch operation between manual mode and programmable mode.