STC-3008 STC-3028 Digital Thermostat Temperature Controller Thermometer Sensor Hygrometer 12V 24V 220V
Features:
Name |
Digital Dual Temperature Controller |
Temperature meauring range |
-55°C~120°C |
Resolution |
0.1 |
Controlling Accuracy |
1°C |
Relay contact current |
10A/240V AC |
Temperature Sensor |
NTC10K |
Length of cable |
1m |
Power supply |
DC 12V 24V/110~220V( choose the one you need ) |
Data Save |
YES |
Working temperature |
0°C~50°C |
Storage Temperature |
-10°C~60°C |
Specifications:
|
|
|
Default |
P0 |
¨ç: Delay start |
0-60 minutes |
0 |
P1 |
¨è: Delay start |
0-60 minutes |
0 |
P2 |
High temperature alarm |
P3~120°C |
120°C |
P3 |
Low temperature alarm |
P2~-55°C |
-55°C |
Long pressUP 1button for 3 seconds, ¨ç display flashes, pressUP 1orDOWN 1button to set the start temperature(25°C default)
Long pressDOWN 1button for 3 seconds, the display flashes, pressUP 1orDOWN 1button to set the stop temperature (40°C default)
Long pressUP 2button for 3 seconds, ¨è display flashes, pressUP 2orDOWN 2button to set the start temperature(25°C default)
Long pressDOWN 2button for 3 seconds, the display flashes, pressUP 2orDOWN 2button to set the stop temperature (40°C default)
Long pressDOWN 1andDOWN 2button for 3 seconds to reset the controllers.
Heating Mode--Start temperature<Stop temperature
Cooling Mode--Start temperature>Stop temperature
Feature:
Be able to control temperature and humidity at the same time.
Be able to connect with humidifier and dehumidifier equipment at the same time.
Be able to connect with refrigeration/ heating and humidifier/dehumidifier equipment at the same time.
Heating/Cooling function could be set separately for refrigeration and heating to protect temperature controller from violent change. Same as humidity Control.
Supporting Temp and Humidity Calibration
[Dual Display Window] Be able to display measured temperature/humidity and set temp/humidity at the same time
Specification:
Model: STC-3028
Input voltage: AC110~220V± 10%, DC24V, DC12V
Measuring temperature range: -20°¢¦+80°
Measuring humidity range: 00%RH¢¦+100%RH
Accuracy: ±1°, 0.1%RH
Relay output contact capacity: 10A/240VAC
Sensor length: 1m
Set startup temperature(humidity):
Press the "up" button once to display the starting temperature(humidity). Long press the "up" button for about 3 seconds,The required temperature(humidity) can be set by the up and down keys
Set stop temperature(humidity):
Press the "down"button once to display the stop temperature(humidity). Long press the button for about 3 seconds and the stop temperature(humidity) number flashes. The required temperature(humidity) can be set by the up and down keys
Temperature/humidity correction:
Press "up" and "down" button at the same time.