I. Product introduction
Y-1 has the characteristics of compact structure, reasonable layout, compact size, light weight and easy to carry. The flaw detector can be directly plugged into the ALTERNATING current, and can also be used with ac magnetization power supply (AC battery pack) and DC magnetization power supply (DC battery pack), high efficiency and light. Suitable for hull weld inspection, high altitude steel structure weld inspection and pressure vessel internal operation. The instrument is suitable for magnetic particle flaw detection of all kinds of iron and steel structural parts, boilers, pressure vessels, pressure pipes, hull welds and ferromagnetic material surface and near surface defects of various types of welded structures in electric power, metallurgy, petrochemical, machinery and other industries.
Two, product features
Three power supply modes can be selected freely:
¡ß Direct plug AC power supply can be directly connected to the USE of AC power supply;
¡ß Where there is no direct ac power supply, AC magnetization power supply (AC battery pack) can be used for power supply to realize ac magnetization flaw detection function;
Dc magnetization power supply (DC battery pack) is optional to realize the function of DC magnetization.
Ac magnetized power supply (AC battery pack) has the protection functions of voltage stable output, overcharge, overcurrent and overdischarge.
Automatic power off when lifting force is not enough to ensure flaw detection sensitivity.
Electric quantity display function, can display the current battery quantity, with sound and light alarm function.
Built-in microcomputer chip, stable output voltage to ensure flaw detection sensitivity.
Magnetization is adjustable
Special working belt, can carry battery pack, magnetic suspension, contrast agent, magnetic yoke probe, etc
(Battery is not included in the price list, 1200 yuan is required for optional battery)
3. Product parameters
1, working temperature: -10 ~ +40¡É
2, storage temperature: -20 ~ 50¡É
3, relative humidity: <80% no condensation
4, working temperature rise: <18¡É
5, temporary load rate: >50%
6, sensitivity: A1 type standard test piece 15/50 grooves clear display
7, ac minimum power lifting force: >4.5kg(44N)
8, dc minimum power lifting force: >18.1kg(177N)
Rechargeable magnetic particle flaw detector: Y-1
Electrode spacing: 0 ~ 210mm
Maximum current: 2.8A
Weight: 2.2 kg
Main functions: ¨ç AC magnetization (direct plug)