|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ÃøÁ¤ ¹üÀ§: salinity refractometer
- ºê¸¯½º ÃÖ¼Ò ´«±Ý: salinity meter
- ºê¸¯½º ¹üÀ§: salinity tester
- Min. Div.: Salinity meter
- ÃøÁ¤ Á¤È®µµ: Refractometer salinity
- Áß·®: 370g
- Å©±â: 121*58*25mm
- ¸ðµ¨ ¹øÈ£: measuring water salinity
- »ç¿ë¹ý: ³óµµ
- ºê·£µå À̸§: SOONDA
- ±Ù¿ø: CN (Á¤Ç°)
- Áõ¸í¼: NONE
- salinity refractometer: pool salinity meter
- Refractometer salinity: salinity tester
- Salinity meter: salt refractometer
- Salimeter: salinometer
- measuring water salinity: juice salt
- salt brine density meter: salinity refractometer parts
- refratometro salinidade: medidor salinidad piscina
- juice salt: juice salinity
- soup salt: soup salinity
- drinking water salt: drinking water salinity
- auto: autorefractometer
- Refractometer: optometry
- Optometry equipment: ophthalmoscoscope
- optometry and optics: refratrometro
¿É¼ÇÁ¤º¸[(200000060)Salt Tester-With box]Auto 0-28% Refractometer Salinity Meter (Salinity )Sodium Chloride Percent Concentration Range: 0.0-28.0%£¨SO1£© Resolution : 0.1% Accuracy :¡¾ 0.2%
(Salinity) Sodium chloride per thousand Range: 0-280¢¶£¨SO2£© Resolution : 1¢¶ Accuracy :¡¾2¢¶
(Salinity )Sodium Chloride Specific Gravity: 1.000¡ª1.217 £¨SO3£© Resolution : 0.001 Accuracy :¡¾0.002
(Salinity) Refractive Index £º1.3330¡ª1.4200nD£¨SO4£© Resolution : 0.0001nD Accuracy : ¡¾0.0003nD Measuring Soup Pool Tap Water Salinity SG Index Autorefractometer Optometry Equipment Ambient temperature: 10-100 degrees Measurement Time: Approximately 1.5 seconds Minimum Sample Volume: 2 metric drops Light Source: Yellow LED Sample Cell: Stainless steel ring and flint glass prism Case Materia: l ABS Enclosure Rating: IP65 Battery Type / Life: 9V / 5000 readings Auto-Off: After 3 minutes of non-use Dimensions: 58*25*121mm Weight: 350g Zero Calibration The meter only supports pure water calibration. The calibration method is as following drop 0.2-0.3ml pure water then close the cover to measure Press 'CAL' button for 2 seconds to enter the calibration status Press ¡°CAL¡± button for 2-3 seconds till see the ¡®CAL¡¯ flashing Press "CAL" button once again during the ¡®CAL¡¯ flashing to start to calibrate. When the calibration is completed showing as following. If no any operations for 10seconds the instrument would return back to booting status If fail to complete the calibration, multi-function display area would show an error code. Temperature exceed the limitations, other error codes could be checked in the appendix error code page. Auto 0-28% Refractometer Salinity Meter Measuring Soup Pool Tap Water Salinity SG Index Autorefractometer Optometry Equipment If press the "Read" button for 2 seconds, the instrument would make the automatic measurements upon programmed times (default 15times), the final value is the average of 15 times¡¯ measurements. After measurements, the multi-functions display area would return back to scale showing status
|
|
|
|
|