|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ºê·£µå À̸§: XMSJ
- ±Ù¿ø: CN (Á¤Ç°)
- DIY ¿ëÇ°: Àü±â
- Áõ¸í¼: ¼¼·ý,NONE
Digital Oscilloscope 20M Bandwidth 100M Sampling Rate Hand-held Mini Oscilloscope Sampling Rate Scene Measurement
¨ç Battery power display, the green part is the remaining power Vertical sensitivity. The unit of/c is omitted here. It can be set as IX mode and X mode. If there is - 1X suffix, it means that the current setting is 10X probe input. Otherwise, it means IX probe input mode. The input mode can be switched through the combination keys. Note that the maximum input voltage withstand is 40V under the probe mode, so do not input voltage signals higher than 40V under the instrument X, because this may damage the oscilloscope. The signal tested in IX mode is 0~40V, and 40~600V is tested at 10X, so when the measured signal is lower than 40V, pull the probe to X, and pull the probe to 10X at 40-600V The maximum voltage Wmax of the measured waveform signal of the measured signal waveform 4 is for reference only (it can be displayed and hidden by pressing the key), the minimum voltage Wrn of the measured waveform signal is for reference only (it can be displayed and hidden by pressing the key), and the peak to peak value vp of the measured waveform signal is for reference only. Note: The peak to peak data is reliable only when at least complete waveforms are displayed on the screen. To ensure high accuracy, the screen displays 1-3 complete periodic waveforms. Press the O key, press the left 8 key, and press the MODE 9 time base. Adjust the meter sample rate on a monthly basis. The w unit triggers the Y horizontal line indicator arrow here. The green arrow at the top is the horizontal baseline of the trigger X vertical indicator arrow ¨ç waveform, It indicates that the voltage here is 0 and the frequency of the measured waveform, where K2 represents K12M represents MH, and the data is only for reference. Note that the data of frequency value is reliable only when at least one complete waveform is displayed on the screen. To ensure high accuracy, the screen displays 1 to 3 complete periodic blanking 3 input coupling indicators. The cattle line represents the stream D coupling input, and the triangle wave icon represents the AC AC coupling input 4 mode indicator. The waveform can be scaled and moved by pressing the MOD key, In the three modes of trigger control, switch the 5 key "right MINIUSB charging port" in turn, and 935mm special collector socket under the 8 key on 05C fast charging day.
|
|
|
|
|