1000V AC/DC Measurement Short Circuit Protection Digital Megger Insulation Resistance Tester
Specification Feature:
1. It is suitable for measuring the insulation resistance of various electrical equipment and insulating materials such as transformer, motors, cables, switches, electrical appliances, etc. 2. Icon display/alarm light on/buzzer alarm three types of alarms to prevent the danger of electric shock. Multiple gears can be selected to measure high and low, and the voltage can be measured after shifting. 3. This instrument is a high?performance digital instrument, with large LCD display, display screen make it easy to read measurements. 4. Insulation resistance meter is beautiful, wide range, high accuracy, high resolution, convenient operation, easy to carry. 5. Resistance short circuit protection makes the measurement safer and more assured. Carry out maintenance, testing and verification of various electrical equipment.
Specification:
Item Type: Insulation Resistance Tester Material: ABS Technical Specification | Technical Index | Display | Large-screen LCD display (maximum 500 counts) | Over-limit indication | HI: The sign appears in the insulation resistance range. | Automatic range | Upper range: 500 count lower range 1 (only within the range of insulation resistance) | Sampling Rate | 2 times/sec | Allowable height | ¡Â2000m for indoor use | Operating environment | Temperature 0¡É-40¡É/Humidity: ¡Â85% | Storage environment | Temperature: -20C-60¡ÆC/humidity: ¡Â90% | Overload protection | Insulation resistance range: AC 1200V/10 seconds Voltage range: AC720V/10 seconds | Withstand voltage | AC6000V (50/60Hz)/5 seconds (between the circuit and the periphery) | Insulation resistance | ¡Ã1000M¥Ø/DC1000V (between the circuit and the periphery) | Power supply | 6x1.5V AA dry battery (not included) | Rated voltage | 100V | 250V | 500V | 1000V | Measuring range | 0-1.5G¥Ø | 0-5.5G¥Ø | 0-5.5G¥Ø | 0-5.5G¥Ø | Open circuit voltage | DC100V+20% -0% | DC250V+20% -0% | DC500V+20% -0% | DC1000V+20% -0% | Standard measuring current | 1mA-1.2mA at 0.1M¥Ø load | 1mA-1.2mA at 0.25M¥Ø load | 1mA-1.2mA at 0.5M¥Ø load | 1mA-1.2mA at 1M¥Ø load | Short circuit voltage | About 2mA | Accuracy | ¡¾5%rdg¡¾3dgt (above 100K¥Ø) | Small resistance measurement | Open circuit voltage | About 5V | Measuring range | 0-999¥Ø | Resolution | 0.1¥Ø | Accuracy | ¡¾(2%+3) | Voltage test |
| DC voltage | AC voltage | Measuring range | ¡¾30-¡¾600V | 30-600V£¨50/60HZ) | Resolution | 1V | Accuracy | ¡¾2%rdg¡¾3dgt |
How to Use: 1: Open the back cover and install 6x1.5VAA dry batteries (not included) 2: Plug in the test lead 3: Measure and rotate to the corresponding gear as required
Package List: 1 x Insulation Resistance Tester(Battery Not Included) 2 x Test Leads 2 x Clip 1 x Cloth Bag 1 x Instruction Manual
APPLICATION
Commonlyused?and?indispensable?instrument?for?electric?power,?post?andtelecommunications,?communications,electromechanical?installation?andmaintenance,?and?industrial?enterprises?that?use?electricity?as?industrialpower?or?energy.?It?is?suitable?for?measuring?the?resistance?value?of?variousinsulating?materials?and?the?insulation?resistance?of?transformers,motors,cables?and?electrical?equipment
|
|
|
|
|