![](https://ae01.alicdn.com/kf/S883b90bcc913474f8eb35ae99d764da0q/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S453bc75ed01f4782b3c7d97f162a3211t/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S96038408ea3f416191d1b86fb8583bdfS/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S7b031a06540d44aa86dfe16f9b92bb59J/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/S883b90bcc913474f8eb35ae99d764da0q/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S453bc75ed01f4782b3c7d97f162a3211t/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S96038408ea3f416191d1b86fb8583bdfS/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/S7b031a06540d44aa86dfe16f9b92bb59J/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg) ![](https://ae01.alicdn.com/kf/Se44a3cd9ce754c6ea91cd34fc225063e1/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg)
- Áß·®: 900g
- Â÷¿ø: 196mmx92mmx54mm
- ÀÛµ¿ ¿Âµµ: -10~50 centigrades
- ÃøÁ¤ ÀδöÅϽº ¹üÀ§: See Details
- ÃøÁ¤ ¿ë·® ¹üÀ§: See Details
- ÃøÁ¤ ÀúÇ× ¹üÀ§: See Details
- ÃøÁ¤ Àü¾Ð ¹üÀ§: AC 0.00V~600V (ETCR4300)
- ÃøÁ¤ ÇöÀç ¹üÀ§: AC 0.0mA~20.0A (ETCR4300)
- ´ëÇü È°ÀÚ: µðÁöÅÐ Àü¿ë
- ¸ðµ¨ ¹øÈ£: ETCR4000,ETCR4000A,ETCR4300
- DIY ¿ëÇ°: ELECTRICAL
- ºê·£µå À̸§: TERRIFIC
- ¿ø»êÁö: Áß±¹
- Model No.: ETCR4000, ETCR4000A, ETCR4300
- Clamp: Double(ETCR4000, ETCR4000A), Triple (ETCR4300)
¿É¼ÇÁ¤º¸[(350686)ETCR4000A 20A 600V] [(175)ETCR4300 20A 600V] [(193)ETCR4000 20A 500V]![](https://ae01.alicdn.com/kf/S2c115b315cf746749301ccd97fd580aen/ETCR4000-ETCR4000A-ETCR4300-0-600-20A-360.jpg_640x640.jpg) ![](https://ae01.alicdn.com/kf/S028f9064481b4b648c50af01543d672ei.jpg) ![](https://ae01.alicdn.com/kf/Seccc34b895e1439998ae355919a71303b.jpg) ![](https://ae01.alicdn.com/kf/S96038408ea3f416191d1b86fb8583bdfS.jpg) ![](https://ae01.alicdn.com/kf/S453bc75ed01f4782b3c7d97f162a3211t.jpg) ![](https://ae01.alicdn.com/kf/S7223c0ec730d4e619929b5ce39f4aac59.jpg) ![](https://ae01.alicdn.com/kf/S871a465dc3d444a7955bbb563f7343d6Q.jpg)
1. ETCR4000 Specifications & Parameters:
Function
|
Phase, AC current, AC voltage, AC leakage current, phase sequence directly test; transformer unit, inductive, capacitive circuit discrimination; power factor, power indirect test
|
Power supply
|
DC9V alkaline batteries (1.5V AA × 6)
|
Power consumption
|
Turn on the backlight most about 35mA, the battery continuously for about 40 hours
|
Turn off the backlight, the instrument consumes about 5mA, for about 300 hours of continuous battery
|
Display mode
|
LCD display, blue backlight, suitable for dark places
|
LCD size
|
70mm × 62mm
|
LCD display field
|
64mm × 54mm
|
Instrument Size
|
Long generous: 196mm × 92mm × 54mm
|
Jaw size
|
7.5mm×13mm
|
Sampling rate
|
About 3 / s
|
Range
|
AC voltage: 0 ~ 20V / 200V / 500V
|
AC current: 0 ~ 200mA / 2A / 10A
|
Phase: 0 ~ 360
|
Measuring the phase of the signal amplitude range
|
When measuring phase U1-U2: 30V ~ 500V
|
I1-I2 phase when measuring: 10mA ~ 10.00A
|
Measured U1-I2 or I1-U2 phase when: 10V ~ 500V, 10mA ~ 10.00A
|
Data Hold
|
Test Press HOLD key to keep data, "DH" symbol display
|
Automatic shutdown
|
Power about 15 minutes, the instrument automatically shut down to reduce battery consumption
|
Voltage detection
|
When the battery voltage falls below 7.8V ~ 8V, low battery symbol appears, reminding replacement battery
|
Instrumentation Quality
|
Host of about 550g (with battery), table clamp about 170g × 2, test line about 250g
|
Test line length
|
1.5m
|
Current Clamp Cable length
|
2m
|
Working temperature and humidity
|
-10 ~ 40 ; 80% Rh or less
|
Storage Temperature and Humidity
|
-10 ~ 60 ; 70% Rh or less
|
Input impedance
|
Test voltage input impedance of the file: 2M
|
U1U2 measured phase voltage input impedance: 40K
|
Withstand voltage
|
Meter line and shell between sine wave AC voltage withstand 1000V / 50Hz lasted one minute; can withstand between the two voltage inputs sine wave AC voltage 500V / 50Hz lasted one minute test
|
Insulation
|
The line between the instrument and the housing, 10M between the two voltage inputs
|
Structure
|
Double insulation
|
2. ETCR4000A Specifications & Parameters:
Voltage
|
Range:0.00V-600V Resolution:0.01V Base error:±(1.5%rdg+3dgt)
|
Current
|
Range:0.0mA-20.0A Resolution:0.1mA Base error:±(1.5%rdg+3dgt)
|
Phase
|
Range:0.0°~360° Resolution:0.1° Base error:±1°(depend on base condition)
|
Frequency
|
Range:45.00Hz~65.00Hz Resolution:0.01Hz Base error:±(2%rdg+3dgt)
|
Active Power
|
Range:0.0W~12kW Resolution:0.1W Base error:±(3%rdg+3dgt)
|
Reactive Power
|
Range:0.0VAR~12kVAR Resolution:0.1VAR Base error:±(3%rdg+3dgt)
|
Apparent Power
|
Range:0.0VA~12kVA Resolution:0.1VA Base error:±(3%rdg+3dgt)
|
Power factor
|
Range:-1~+1 Resolution:0.001 Base error:±0.03
|
Data Hold
|
1500sets, with RS232 interface, convenient for data upload and data management
|
Automatic Shutdown
|
Automatic shutdown about 15 minutes later after launching to reduce battery consumption
|
Line Length
|
Test Line Length: 1.5m;Current Clamp Length:2m
|
Humiture
|
-10~ 40 below 80%Rh
|
Insulation
|
≥10MΩ between meter lines and shell or between the two voltage inputs
|
Structure
|
Double insulation, with insulation vibration-proof sheath
|
SafetySpecifications
|
IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, Pollution Degree:2
|
Accessories
|
Meter:1pc; Current Clamp:1pc; test line:4pc; RS232:1pc; battery(LR6)6 pc; case:1pc
|
Function
|
Simultaneous measurement of two AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc
|
Power
|
DC9V alkaline batteries 1.5V AA×6
|
Display Mode
|
LCD display, 240dots×160dots
|
Consumption
|
About 80mA at most with enabled backlight, battery working continuously for about 10 hours About 50mA with disabled backlight, battery working continuously for about 16 hours
|
Meter Size
|
Length, Width, Height196mm×92mm×54mm
|
3. ETCR4300 Specifications & Parameters:
Function
|
Simultaneous measurement of three-phase AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
|
Power
|
DC9V alkaline batteries(1.5V AA×6)
|
Consumption
|
About 80mA at most with enabled backlight, battery working continuously for about 10 hours
|
About 5mA with disabled backlight, battery working continuously for about 16 hours
|
Display Mode
|
LCD display, 240dots×160dots
|
Meter Size
|
Length, Width, Height 196mm×92mm×54mm
|
Clamp Size
|
acuminate current clamp:7.5mm×13mm
|
Measurement Range
(automatic shift)
|
AC Voltage0.00 V-600V (automatic shift)
|
AC Current 0.0mA-20.0A (automatic shift)
|
Phase 0-360°
|
Frequency 45.00Hz-65.00Hz
|
Active Power 0.0W-12kW
|
Reactive Power 0.0W-12kVAR
|
Apparent Power 0.0W-2kVA
|
Power Factor -1-+1
|
Current Vector Sum 0mA-60.0A
|
Resolution
|
Voltage AC 0.01V
|
Current AC 0.1mA
|
Phase 0.1°
|
Frequency 0.01Hz
|
Active Power 0.1W
|
Reactive Power 0.1VAR
|
Apparent Power 0.1VA
|
Power Factor 0.001
|
Current Vector Sum 1mA
|
Phase Sequence
|
Positive Phase Sequence U1 U2 U3 or I1 I2 I3 cursors blink in order from left to right
Negative Phase Sequence U1 U2 U3 or I1 I2 I3 cursors blink in order from right to left
|
Sample Rate
|
About 2 times/second
|
Data Hold
|
Press HOLD key to keep data, "DH" symbol appears
|
Data Storage
|
500 sets
|
RS232 Interface
|
USB-RS232 interface, download data to computer for analysis and management
|
Automatic Shutdown
|
Automatic shutdown about 15 minutes later after launching to reduce battery consumption
|
Backlighting
|
Suitable for dark place and nightly use
|
Voltage Detection
|
Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 7.2V.
|
Weight
|
Main Unit about 550g(with battery), acuminate current clamp about 170g×3, round current clamp about 185g×3, test line about 250g
|
Test Line Length
|
1.5m
|
Current Clamp Length
|
2m×φ5mm
|
Working Temperature and Humidity
|
-10c-40c below 80%Rh
|
Storage Temperature and Humidity
|
-10c -60c below 70%Rh
|
Input Impedence
|
Testing voltage the input impendence is 2MΩ
|
Withstand Voltage
|
Withstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs
|
Insulation
|
≥100MΩ between meter lines and shell or between the two voltage inputs
|
Structure
|
Double insulation, with insulation vibration-proof sheath
|
Safety Specifications
|
IEC61010-1 CAT iii 600V, IEC61010-031, IEC61326, 2 class of pollution
|
Accessories
|
Main Unit: 1 pc; Meter Box: 1 piece; Current Clamp: 3 pcs; Test Line: 4 pcs(yellow, green, red, black); RS232 Data Line: 1 pc; Disk: 1 pc;User Manual: 1 pc ; Guarantee Card: 1 pc; Certification: 1 pc.
|
![](https://ae01.alicdn.com/kf/Sa6dfd119b9a14a79b514253e499c4f5av.jpg) ![](https://ae01.alicdn.com/kf/Se44a3cd9ce754c6ea91cd34fc225063e1.jpg)