![](https://ae01.alicdn.com/kf/Sa11aa5a3bf294910ae3663f0301e4c49i/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/S4a692a58fd2e49eabd807b2ebb49a41dC/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/S8af3e3c61a604bd09a2a7614b1a719f7g/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/Se4561d5a410b468cafeca00cbc814c9fv/AC50-300V-100A-110V-220V-240V-LCD.jpg)
aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Sa11aa5a3bf294910ae3663f0301e4c49i/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/S4a692a58fd2e49eabd807b2ebb49a41dC/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/S8af3e3c61a604bd09a2a7614b1a719f7g/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/Se4561d5a410b468cafeca00cbc814c9fv/AC50-300V-100A-110V-220V-240V-LCD.jpg)
![](https://ae01.alicdn.com/kf/S471f00e2262d4c9f93690279fc911c42l/AC50-300V-100A-110V-220V-240V-LCD.jpg)
- ºê·£µå À̸§: Aideepen
- DIY ¿ëÇ°: Àü±â
- ±Ù¿ø: CN (Á¤Ç°)
- Â÷¿ø: 4.9*4.7*5.3
- ÀÛµ¿ ¿Âµµ: Free
- Á¤È®µµ µî±Þ: 0.01
- ´ëÇü È°ÀÚ: µðÁöÅÐ Àü¿ë
- Àü·Â °ø±Þ: AC
- Áõ¸í¼: NONE
- ¸ðµ¨ ¹øÈ£: AC50-300V 100A
¿É¼ÇÁ¤º¸
[(350850)AC 250-450V]
[(350853)AC 50-300V]![](https://ae01.alicdn.com/kf/A662c099d20764d6ebc55ac2f23ca3687l/AC50-300V-100A-110V-220V-240V-LCD.jpg_640x640.jpg)
![](https://ae01.alicdn.com/kf/Sf43de78f9a6c47e78190468d95f7d9d7d.jpg)
Product selling point
1: LCD color display true color screen 178 degrees wide viewing angle
2: Measure AC voltage, current, power, power, frequency, power factor (6 major functions)
3: The power (Kwh) has a memory function. Press and hold the round hole on the side of the meter for 5 seconds to clear the accumulated power consumption.
4: Widely used in measurement application industry, chemical industry, power plant, automation equipment, DOS system, electromechanical equipment and other places
5: Simple to use, provide wiring diagram
6: Display color: red orange yellow white green blue
The digital multi-function meter can measure and display 6 parameters such as AC voltage, AC current, active power, power factor, frequency and electric energy at the same time. The instrument display part adopts a color high-definition LCD screen.
Main Specifications
1. Measurement accuracy: 1% ¡¾ 2 words
2. Measuring range: AC voltage: AC50.0-300.0V, (or AC250.0-450.0V can be customized as needed),
AC current: AC0-99.99A, the current display resolution is 0.01A, when it exceeds 100A, it will display 100.0A
Power frequency: 45.0Hz-65.0Hz
Power factor: 0.00-1.00PF
Active power: the measurement range is 0-45000W, the display resolution between 0-9999.9W is 0.1W, the rest is 1W
Electric energy: The measurement range is 0-99999kwh, the minimum display resolution is 0.01kwh for 0-999.99kwh, and the minimum display resolution for 10000.0-9999.9kwh is 0.1kwh,
10000.0-99999kwh minimum resolution is 1kwh
3. Measurement speed: about 2 times per second
4. Dimensions: 49¡¿47¡¿52(mm)
5. Hole size: diameter ¥Õ22mm
6. Save function/memory function: Auto save function: When the power is off, the meter will automatically save the current energy value, and the meter will read the value after the next power on, and continue to accumulate.
How to use and connect
1. Connect according to the wiring diagram in the attached drawing, and insert the two-wire plug of the secondary terminal of the current transformer with the instrument into the secondary input terminal of the instrument transformer. Pass the main circuit wire of the current test through the middle round hole of the current transformer.
2. Connect the voltage measurement lead to the measurement voltage input terminal of the instrument. Then turn on the measurement voltage. Start reading measurement results.
3. The power reset button of the meter is on the lower right side of the meter. When power reset is required, use a circle with a diameter of less than 2mm to hold it in the reset hole for 5 seconds, and the accumulated power value can be reset to zero.
Precautions
The meter with the range of 250-450V is only suitable for the mains power supply of pure AC 50V, and cannot be used for square wave, inverter output and corrected sine wave circuit measurement, otherwise the meter will be damaged. Meters in the 50-300V range are not affected.
list
1*Multifunctional voltage current power display frequency meter
![](https://ae01.alicdn.com/kf/S086303237c9a4f34b154ddb18843369cH.jpg)
![](https://ae01.alicdn.com/kf/Sa5af92825d554a9bb69462ed81dcca8b3.jpg)
![](https://ae01.alicdn.com/kf/S28cdd856d2d345159e091c6f0138be902.jpg)
![](https://ae01.alicdn.com/kf/S5478255cba7e44d88c01c7b3ee8c1b7eH.jpg)
![](https://ae01.alicdn.com/kf/S89573f86dd6a44a8b79cf63caca2fd15g.jpg)
![](https://ae01.alicdn.com/kf/Sc3a391bbf54243e5b4b921b27ce217ffR.jpg)
![](https://ae01.alicdn.com/kf/Se4ba0d13194a4556bfa740704342b498Z.jpg)
![](https://ae01.alicdn.com/kf/S73157d94ec324b708afbb2c0c7d746b0H.jpg)
![](https://ae01.alicdn.com/kf/S7bec50489e4a411d9baa8781d91266c4C.jpg)
![](https://ae01.alicdn.com/kf/Sa480e57aa3fd4c9ab6a3f2b71302e3631.jpg)
![](https://ae01.alicdn.com/kf/S966bd457333146e79bf1a477fdb4d75aY.jpg)
![](https://ae01.alicdn.com/kf/Sc537253fb18d4b6d8055da22b3e5d0c8k.jpg)
![](https://ae01.alicdn.com/kf/S42404f4d062840ac887cb21f68b3e28cL.jpg)
![](https://ae01.alicdn.com/kf/Sfa742bc6491348c0b31d2239011b8263S.jpg)
![](https://ae01.alicdn.com/kf/S8426a3f760b140b5973a3817824e8bb2H.jpg)
![](https://ae01.alicdn.com/kf/Sa0af77ae205246829181e18d5f43bb957.jpg)
![](https://ae01.alicdn.com/kf/S5f7f864ecde84895897eb4104d08766fx.jpg)