![](https://ae01.alicdn.com/kf/Sf8e0d7cb03bf4bd18dc6e6b4301f7106K.png)
![](https://ae01.alicdn.com/kf/S6690f7ecee1f4ab782f9d88500d3e10ec.png)
UA6013L Multimeter Auto Range Digital LCD Capacitor Capacitance Test Meter Multimeter Meter Capacitance Test Meter With 2 Probes
Features:
6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD.
Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,00F.
It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
Wide measuring range, covering 9 measuring sections from 0.1pF to 20,00F that Package Included: nominal value of any capacitance.
Specifications:
Color:Grey+Red
Dimension:148 x 75 x 33 mm
Package Included:
1 x Capacitance Tester
2 x Probes
Notes
a. If you don't know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
b. If the capacitance is in short circuit, the meter shows ""beyond measuring range"". If the capacitance is in electric leakage, the meter shows ""beyond measuring range"" or ""much bigger than the normal value"". If the capacitance is open-circuit, the meter shows ""Zero"" or ""several pF "".
c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
Maintenance
The meter is of highly accurate electronic apparatus. Don't change its internal circuit rashly for no damage to the meter.
1. Don't exert electric voltage upon the jack parts of the meter for no damage to the meter.
2. Don't test the sensors in short circuit , or the battery will be consumed out quickly.
3. Don't use a meter whose back cover doesn't cover the meter well.
4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is
![](https://ae01.alicdn.com/kf/H4ef4033ea72f4af7b258be66b9fe62a0L.png)
![](https://ae01.alicdn.com/kf/S7dbc49c564fa405292df6f4cced38a4e7.jpg)
![](https://ae01.alicdn.com/kf/S4625dfadb0ad46ce8d9bd9b1197a7e02B.jpg)
![](https://ae01.alicdn.com/kf/Sdd66eb6a0f984a9b967bc18e91c9b5a0e.jpg)
![](https://ae01.alicdn.com/kf/S9e311ea00aa147d0af43fa8471809ea23.jpg)
![](https://ae01.alicdn.com/kf/Sd4ff2fb452984d089c442bd4cc5b6b90k.jpg)
![](https://ae01.alicdn.com/kf/S939e71c54d9e4ad4bb6fa7b111acffc9X.jpg)