![](https://ae01.alicdn.com/kf/Sebafe90d9a614e819df237ce3922bfedq/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S34712ade95de44da80639341d88f0d7eK/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S0cf7a9ece11f4ebca4cbf4b499125429B/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S0acf57f5ab084e7696a80d585e541b5dz/MASTECH-MS2108-6600-RMS-AC-DC.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Sebafe90d9a614e819df237ce3922bfedq/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S34712ade95de44da80639341d88f0d7eK/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S0cf7a9ece11f4ebca4cbf4b499125429B/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/S0acf57f5ab084e7696a80d585e541b5dz/MASTECH-MS2108-6600-RMS-AC-DC.jpg) ![](https://ae01.alicdn.com/kf/Sb8526d32adb14ee3a1ee646728c07583n/MASTECH-MS2108-6600-RMS-AC-DC.jpg)
- ºê·£µå À̸§: ZOYI
- ±Ù¿ø: CN (Á¤Ç°)
- DIY ¿ëÇ°: Àü±â
- ´ëÇü È°ÀÚ: µðÁöÅÐ µð½ºÇ÷¹ÀÌ
- Áõ¸í¼: NONE
- ¸ðµ¨ ¹øÈ£: Digital Clamp Meter Multimeter 6600 Counts
- ÀÛµ¿ ¿Âµµ: 0 - 40¡É
- Model Number: MS2108
- Measuring Resistance Range: 660ohm/6.6kohm/66kohm/660kohm/6.6Mohm/66Mohm
- Operating Mode: A/M
- Measuring Inductance Range: See Description
- Measuring Capacitance Range: 6.6uF/66uF/660uF/6.6mF/66mF
- Dimensions: 208x78x35 mm
- Item: AC DC digital clamp meter current tester 600A
- Storage temperature: -10~50C.10F~122F
- Auto range function: yes
- Auto power off time: 30 min.
- Diode test: yes
- Continuity buzzer: yes
- power supply: 1.5V*3 AAA batteries(not included)
- Feature 1: MS2108 Digital Clamp Meter Multimeter
- Feature 2: Capacitance Frequency Inrush Current Tester Multimeter
Multitester MASTECH MS2108 Digital Clamp Meter Multimeter 6600 Counts True RMS AC DC Capacitance Frequency Inrush Current Tester
Please note:send without battery
Features: In line with GB / T 13978-92 General technical requirements of digital multimeter In line with GB4793.1-1995 (IEC-61010-1) Safety requirements for electronic measuring instruments Belong to two pollution, over-voltage standard CAT III 600V INRUSH (surge) measurement function Frequency measurement function clamp Clamp head lighting function Automatic / manual range Data Hold Max / Min Measurement Off test Diode test Maximum jaw opening size: Φ26mm Automatic shutdown / background light AC voltage / current True RMS measurement Display: maximum display number 660
Technical Parameters: DC Current: 66A / 600A ± 3.0% AC current: 66A / 600A ± 3.0% DC voltage: 660mv / 6.6v / 66v / 600V ± 0.8% AC voltage: 660mv / 6.6v / 66v / 600V ± 1.0% Resistance: 660Ω / 6.6kΩ / 66kΩ / 660kΩ / 6.6MΩ ± 1.0%; 66MΩ ± 2.0% Capacitance: 6.6μF / 66μF / 660μF ± 4.0%; 6.6mF / 66mF ± 4.0% Frequency: 10 ~ 10kHz ± 2.0% (measured by the input terminal) Frequency: 10 ~ 1kHz ± 2.0% (measured by the clamp head) Duty cycle: 10% ~ 95% ± 3.0% Power: 1.5V (AAA) × 3 (not included)
Package including: 1*Digital Multimeter 2*Test Leads 1*Soft bag 1*Instruction Manual
![](https://ae01.alicdn.com/kf/S770931c047ea4132adc3e594c6e5a04ca.jpg)
![](https://ae01.alicdn.com/kf/S9f5fe367680b4fc4a6eba28ed9f1cf132.jpg)
![](https://ae01.alicdn.com/kf/Sf717d2ca834044ff9956e4dbddf275b48.jpg)
![](https://ae01.alicdn.com/kf/S65d193b6f29b4e8992a27df3db7a8979F.jpg)
![](https://ae01.alicdn.com/kf/Sb4c62e615cd8446a9b616006140ef92eL.jpg)
![](https://ae01.alicdn.com/kf/S0883eaefd09141e680db344e8403730fM.jpg)
![](https://ae01.alicdn.com/kf/S562bbdda73744935b574d244974074beg.jpg)
![](https://ae01.alicdn.com/kf/S8ebb5604c8d648638aa73a63fb5249e1t.jpg)
![](https://ae01.alicdn.com/kf/S486aa2a3d7f44390bb7a14a9ec427693o.jpg)
![](https://ae01.alicdn.com/kf/Sdd208231af294a0fb12cad60fc1b6238W.jpg)
|