|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ºê·£µå À̸§: MIRONG
- ±Ù¿ø: CN (Á¤Ç°)
- ½º¸¶Æ® ±â±â: YES
- µð½ºÇ÷¹ÀÌ À¯Çü: DIGITAL
- ¹é¶óÀÌÆ® ¿É¼Ç: YES
- ¸ðµ¨ ¹øÈ£: PNO3-1-01
- Áõ¸í¼: ¼¼·ý,DOT,EAC,EPA,FCC,GMP,ROHS,TGA,Ul,KC,pse,weee,NONE
The ion selective electrode is logarithmic ion activity in the solution was given potential and electrochemical sensing element linear relationship, electrochemical sensor for determination of ion activity or concentration in the solution of a class of the membrane potential belongs to membrane electrode, its core part is the induction of membrane electrode tip. Ion selective electrode method is a branch of potential analysis, which is generally used for direct potentiometric method, and can also be used for potentiometric titration. The characteristic is that the concentration of specific ion in the solution can be determined, and the application range is wide, and the effect of the reagent color and turbidity is not affected. Application of ion selective electrode Ion selective electrode analysis is very wide, as long as the correct choice of ion measurement methods, ion meter and electrode can be measured the concentration of the corresponding ion. It has been successfully applied in the fields of environmental monitoring, water quality monitoring, soil analysis, food detection, drug analysis, etc.. Ion electrode applications by industry industry | Ion measurement | Aquaculture | Ammonia, nitrate | Papermaking | Sodium, chlorine, calcium | Steam and electricity | Chlorine, residual chlorine, sodium, calcium, ammonia | Agriculture | Calcium, sodium, potassium, chlorine, fluorine, bromine, iodine, tetrafluoroborate, nitrate and cyanide | Food /Drinks | Chlorine, fluorine, iodine, calcium | Metallurgy /Electroplate | Copper, fluoride and cyanide, | seawater | Sodium, chloride, nitrate, fluoride, ammonia nitrogen | Natural water body | Potassium, calcium, sodium, bromine, chlorine, fluorine, iodine, silver, nitrate | Drinking water | Chlorine, nitrate, fluoride, copper
|
Model | measuring range (mol/L) | temperature range (c) | Shell Material Science | Outline dimension (mm) | Connector | PF-1/PF-1-01Fluorine ion | 10-1-10-6 | 5-45 | Glass | Phi 12 * 120 | Line /BNC | PCl-1-01 PCl-1/Chloride ion | 10-1-5 * 10-5 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PK-1/PK-1-01potassium ion | 10-1-10-5 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PCa-1/PCa-1-01calcium ion | 10-1-10-5 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PNO3-1/PNO3-1-01Nitrate ion | 10-1-10-5 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PBF4-1/PBF4-1-01Fluoroborate ion | 10-1-3 * 10-6 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | Ag-S-1/P Ag-S-1-01 PSilver sulfur ion | 10-1-3 * 10-7 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PPb-1/PPb-1-01Lead ion | 10-1-5 * 10-7 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PCN-1/PCN-1-01Cyanide ion | 10-2-10-6 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PI-1/PI-1-01Iodide ion | 10-1-5 * 10-7 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PCu-1/PCu-1-01copper ion | 10-1-5 * 10-7 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PBr-1/PBr-1-01Bromide ion | 10-1-5 * 10-6 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | PClO4PClO -1/4-1-01 | 10-1-10-5 | 5-60 | Plexiglass | Phi 12 * 120 | Line /BNC | 6801(zero potential 0Sodium ion | 10-1-10-6 | 20-40 | Glass | Phi 12 * 120 | In line | 6801A(zero potential 2Sodium ion | 10-1-10-6 |
|
|
|
|
|
|