Product parameters
Parameter function description
00 Mode setting: 0=basic mode; 1=basic mode plus back-off.
01 Positioning accuracy: unit is +/-0.01MM
02 Recession length: Recession length setting (unit MM)
03 Transmission coefficient: transmission ratio: pulse / transmission ratio = MM
04 Deceleration distance: the distance before the target position (unit MM)
08 Positioning time: set to stay at the target position to a certain time (unit: 0.1 seconds)
06 Slow speed: set value 0.5-0.05, usually 0.2-0.1 (unit: 0.1 second)
07 Front limit: The set value is set according to the specific situation of the machine. (unit MM)
08 Rear limit: The set value is set according to the specific situation of the machine. (unit MM)
1. Press and hold the [Program] key for about 3 seconds
2. A flashing P appears in the program bar
3. Press the [+] [-] keys to select the parameter to be modified
4. Then press the [ENT] key
5. To exit the parameter setting state, press - - times [Program] key to exit the main screen
6 After the parameter setting is completed, turn off the power and then turn on the power again to save the data.
Operation and switching output description
The working process is: after pressing the run key,
Assuming that the difference between the actual position and the target position is 2MM (the deceleration distance can be set by parameters), the RI terminal outputs the potential
signal; if the difference between the actual position and the target position is less than the deceleration distance, the RI terminal will output a pulse signal
(slow signal), the running indicator on the panel flashes fast and slow respectively, indicating fast or slow running status,
When the actual position and the set position are equal, the running indicator light will be on for a long time, indicating that the stop is in place.
But there is another parameter to decide the stop, which is parameter 5.
Parameter 5 can set the time when the actual position and the set position coincide (dwell), so that the positioning can be more accurately positioned at the set position.
fixed location.