0.001g Precision Jewelry Carat Scale Digital LCD Fixed-number Warning Gold Medicinal Lab USB Balance Weight Scales 50g/80g/100g
Description:
Thank you very much for choosing this digital balance. It is a kind of digital balance that can stand freely with portable & space-saving volume.
This product uses a new type of sensor with high precision and sensitivity, which makes the weighing more accurate and responsive.
With the HD LCD display,it can meet your weighing needs! Product functions are quite complete, please read this product manual carefully before use!
Specification:
1.Product size: 204.5X131.5X39.5MM
2.LCD Display size: 55X21.5MM
3.Salver size: Diameter 112mm
4.Power supply: 3xAAA(Not Included)& USB(Included)
5.Function buttons:
UNIT(g. oz, ct, ozt, dwt, tl, gn), TARE, CAL(calibration), PCS(counting), F-W(Fix-number Warning),ON/OFF(power on/power off)
6.Backlight: White
7.Auto power off(Can be set freely)
8.Operation temperature: 10-30°C
9.Unit can be turn off/on
10.One step calibration function
11.7 units: g,oz,ozt,dwt,tl,ct,gn
12.Tare function
13.Capacity:50g/0.001 80g/0.001 100g/0.001
Accuracy:0.001g
Minimum starting value:0.003g
(When it overloads 9 graduation, it will display FULL)
14.Weight: 420g Size: 24*15.9*9cm
ON/OFF:
Press once in shutdown state to turn on, and once in shutdown state to turn off.
TARE:
TARE: When weighing, press TARE once, it displays - 0 ? then goes zero.
You can remove the tare weight by this way when using the protective cover as the weighing tool.
Auto power off time setting:
Press TARE for 3-4 seconds in power on state to display AU 0-300.
Press UNIT key to select the automatic shutdown time as you need. 0 is not automatic shutdown, the maximum shutdown time is 300 seconds. After selection, press the TARE key to confirm and it display PASS. The setting is completed.
UNIT:
Press UNIT to switch weighing units(g. oz, ct, ozt, dwt, tl, gn)
Unit hidden function: Press UNIT key for 4 seconds, all the units will light up and unit OZ blink, then press TARE to hold or close this unit, Press UNIT to select next unit, unit g can not be closed.
Press UNIT for 4 seconds to return normal weighing state.
PCS:
(1) Take samples. The counting sample value of this product is (25,50,75 100). In order to count accurately, if the single weight of the product is less than or equal to the graduation value, the maximum sampling value (100) is required. If the single weight is more than the graduation value, you can select a small number of sample values (25,50). In principle, the single weight is more than the graduation value to be more accurate. If you count 25 samples (the same item) and put them on the scale, the weight of 25 samples will be displayed on the scale. At this time, press the PCS key for a long time, and the LCD will display the flashing PCS + P25. Press UNIT key to select other sample values (you can select as many as your samples).
Press the PCS key again to confirm, and the LCD will display 25 PCS. load the same items and count them according to your requirements Now.
CAL:
Press the CAL or ON/OFF button to enter the user calibration interface,
Displays the current maximum scale of flicker, When a single point calibration directly loads the appropriate weight (changing the weight by
TARE or UNIT), the calibration is completed PASS and the current weight value is displayed. If you need two calibration, Press CAL again (or turn on the key once) for 1000 G/0.01 to show flashing ADD 500, Calibration, Display 500.00 and display flashing A 1000, immediately (i.e .500 G weights) calibrated to display PASS and display a stable 1000.00.
Fixed-number Warning Key:
1.Set the alarm lower (x) weight value
2.set the alarm higher than (x) weight value
3.Set less than (x) quantity value (counting mode)
4.Set quantity value higher than (X) (counting mode)
Package List:
Carat Scale
Calibration Weights
USB Cable
Tweezers
Portable Bag
Paper Box