Product description
The multi-function relay control module is specially designed for users with many different needs. It uses a microcontroller as the main control unit and presets 32 functions, and users can use corresponding specific functions according to actual needs. It can be applied to water pump control, motor control, light strip control, solenoid valve control and so on.
1. Brand-new upgrade, the module function is increased to 32 kinds, to meet the needs of more applications.
2. The power supply anti-reverse connection function will not damage the module due to the wrong power supply connection.
3. Timing accuracy to 0.01 second timing. 0.1 second (minimum) ~ 999 minutes (maximum) optional
4. Low power consumption and power saving settings, you can turn off the display area.
Product parameters:
Commodity name: Multifunctional delay relay
Relay V number: DC5V/12V/24V optional
Input voltage: 5V version: DC5V power supply; 12V version: DC12V power supply; 24V version: DC24V power supply
Output load: within DC 30V, maximum 10A. Within 250V AC, the maximum is 5A.
Trigger signal: 5V version (high level: 5V); 12V version (high level: 12V), 24V version (high level: 24V) low level is 0V.
Quiescent current: 20mA
Working current: 60mA
Working temperature: -25¡É-85¡É
Power-off memory: Yes
Product weight: ?26g, product size: length 65 width 34.3 height 17.5 (MM)
Manual measurement is for reference only, the actual size is subject to the actual product
Pin description
DC+: Positive input DC power supply
DC-: Input the negative pole of the DC power supply
IN+: Positive signal input terminal
IN-: Signal input terminal negative
NO: Normally open terminal interface of the relay. When the relay is closed, it is short-connected to COM, and it is suspended when it is not closed;
COM: Relay common terminal interface
NC: Normally closed terminal interface of the relay. When the relay is not closed, it is short-connected to COM, and it is suspended when it is closed;
Tips:
1. Please select the required V number version (according to the above relay identification difference, the relay is 5V instant 5V version) to avoid wrong purchase.
2. The relay output is a passive contact, without current output, which controls the on-off function of a line.
3. Please input the trigger voltage strictly according to the selected version
Instructions for use:
Working mode (32 types):
P-11: Jog mode, pull-in with signal, disconnect without signal.
P-12: Self-locking mode, the state of the relay flips once after each trigger.
P-13: After triggering, the relay pulls in and disconnects after a delay of time A; triggering is invalid during the delay.
P-14: After triggering, the relay pulls in and turns off after a delay of A time; triggers and re-times during the delay.
P-15: After triggering, the relay pulls in and turns off after a delay of time A; the accumulative timing is triggered during the delay.
P-16: After triggering, the relay pulls in and disconnects after a delay of A time; triggers reset during the delay (relay disconnects).
P-17: After triggering, the relay is closed during the signal duration, the input signal disappears, and it is disconnected after a delay of A time; during the delay period, the relay is triggered again and keeps picking, and the timing stops until the last signal disappears, and the delay time is A After disconnecting.
P-18: After the power is turned on, the relay will be closed immediately and will be turned off after a delay of A seconds; until the next power on.
P-21: Give the signal, and the relay will be closed after delaying time A.
P-22: Give a continuous signal. After the time A exceeds, the relay is closed; the signal disappears and the relay is disconnected.
P-23: When the signal disappears for more than time A, the relay is closed; when there is a signal, the relay is disconnected.
P-24: Give a continuous signal. After the time A exceeds, the relay will be closed; if the signal disappears for more than the time A, the relay will be disconnected.
P-25: Give continuous signal, after time A is exceeded, the relay will be closed; give continuous signal again, after time A, the relay will be disconnected
P-26: Give the signal, and the relay will be disconnected after being closed for A time; after the signal disappears, the relay will be closed again for A seconds and then stop
P-27: With pulse signal (rising edge or falling edge), the relay is disconnected, and there is no pulse signal. The relay will pull in after a delay of A time (continuous high level or continuous low level is considered as no pulse).
P-28: After power-on, the relay will be closed after the delay time A until the power is off.
P-31: After power-on, the relay will pull in for A time, disconnect for B time, infinite loop; power off stops.
P-32: There is a continuous signal, the relay is closed for A time, disconnected for B time, infinite loop; when the signal disappears, the loop is terminated.
P-33: Give a signal, the relay will pull in for A time, and disconnect for B time, infinite loop; give another signal to terminate the loop.
P-34: After power-on, after delaying time A, the relay will be closed, and will be disconnected after the time B is closed.
P-35: Give a signal, after delaying time A, the relay will be closed, and will be disconnected after the time B is closed.
P-36: Give a continuous signal. After the time A exceeds the time, the relay is closed, and the relay is closed after the time B is closed; the signal disappears, the timer is cleared, and the relay is disconnected.
P-37: When there is a signal, the relay will be automatically disconnected after the A time is closed, and then the B time will be counted after the disconnection. The signal trigger is invalid within the A+B time.
P-38: When there is a signal, the relay will be automatically disconnected after the A time is closed, and after the B time is counted after disconnecting, it will be automatically disconnected after the A time is closed again.
P-41: No action when there is a signal; trigger when the signal disappears; the relay pulls in and disconnects after the delay time A.
P-42: The signal disappears, the relay will be closed after the delay time A; after the delay time B the relay will be disconnected.
P-43: The signal disappears, and the relay is closed after the disappearance exceeds the A time; the relay is disconnected after a delay of B time.
P-44: After power-on, the relay will pull in for A time and disconnected for B time; after cycling C times, the relay will disconnect and stop.
P-45: No action after power-on; after the signal is given, the relay pulls in for A time and disconnects for B time; after the cycle C times, the relay is disconnected and stopped; when the signal is given, it is executed again.
P-46: After giving the signal more than A times, the relay will be closed; keep closed; power off and stop.
P-47: After giving the signal more than A times, the relay will be closed; after the B time has been closed, it will be disconnected.
P-48: In the C time, after the signal is continuously given for more than A times, the relay will be closed and disconnected after the B time.
The position of the decimal point and its time unit description table:
The decimal point of x.xx is in hundreds, and the time range is 0.01~9.99 seconds
xx.x The decimal point is in the ten place, and the time range is 0.1~99.9 seconds
xxx has no decimal point, and the time range is 1~999 seconds
xxx. The decimal point is in the ones place, and the time range is 1~999 minutes
Turn off the display: In the non-setting state, press K4 to turn off the display, then press again to turn it on again.
Working parameter setting description:
Press and hold the K1 button without letting go, the display will show P-xx after 2 seconds, press K2 and K3 to change the working mode. After selecting the working mode, short press the K1 key to enter the A time setting, and the screen displays Axxx. At this time, press the K2 and K3 keys to modify the A time parameter. Short press the K2 and K3 keys to add or subtract 1, and long press to quickly add or subtract 10. Press the K4 key to set the position of the decimal point. After setting the A time, press the K1 key to set the B time, and the screen displays bxxx. At this time, press the K2 and K3 keys to modify the B time parameter. Short press the K2 and K3 keys to add or subtract 1, and long press to quickly add or subtract 10. Press the K4 key to set the position of the decimal point. After setting the B time, press the K1 key again to set the C cycle number parameter, and the screen displays Cxxx. At this time, press the K2 and K3 keys to modify the C cycle number parameter, and the K2 and K3 keys Short press to add or subtract 1, long press to quickly add or subtract 10. After the setting is completed, press the K1 key one last time to exit the setting state and save all parameters.