Electronic Counter Proximity Industrial Magnetic Sensor Switch Digital Display Punch Counter Automatic Induction Counter Meter
Technical parameter:
Power supply: 1.5V -- AA battery (not included)
Reset method: panel/external
Counting range: 00000---99999 Clear small pulse width: 0.1 seconds
Counting frequency: 20HZ Ambient temperature: -5¦¡40¡É
Counting small pulse width: 10mS Dimensions: 64*38*38mm
Magnet induction proximity distance: about 10mm
Open hole size: 61*36mm
Magnet induction distance: ¡Ã 35 mm
Weight: about 120g
Sensor cable length:1.1m
Install the battery:
Be sure to install the battery before use!
Unscrew the 2 housing fixing screws, gently separate the back cover (be careful not to break the signal cable), and install a AA battery.The battery can be used for more than a year and a half), close the back cover, and screw back the 2 case fixing screws.
Start counting:
connect the magnetic control induction switch VJ12-D10K to the counting terminal, and then flexibly install the magnetic control induction switch and magnet on the corresponding position of the equipment according to the actual work needs, so that the equipment that needs to be counted can complete a work process , the magnet also approaches and then leaves the magnetic control induction switch once.
When working, let the magnet move with the device, close to the magnetic control induction switch at a distance of about 1 cm, and then let the magnet leave the magnetic control induction switch at a distance of more than 3.5 cm, the counter +1 counts, repeat the above process, the counter will accumulate count: 0 , 1, 2, 3, 4, 5, 6... (Note: counts when the magnet leaves). When installing, please adjust the position and distance of the magnet and the induction switch.
Pause counting: Press the count/pause key (PAUSE) to pause the count, and press the count/pause key (PAUSE) again to resume the count.
Clear: directly press the reset key (RESET), the counter is cleared; or: the reset terminal is connected to a button switch (sold separately), the button switch is turned on, and the counter is cleared;
Notes and instructions:
1. The signal line for counting and clearing input should be as short as possible, and avoid wiring with strong electricity or power lines to avoid unnecessary interference; if necessary, please use shielded line, and the shielding layer is connected to the clearing terminal - .
2. The counting signal and the clearing signal can only input the contact signal, and no other electrical signal can be input.
3. The sensing distance is related to the magnetic size of the magnet. You can change the sensing distance by changing different magnets.
4. The use temperature of the magnet cannot exceed 70 degrees. If the temperature is too high, the magnetism will disappear and the induction will fail! !
5. When the LCD screen is blurred, please replace the battery with a new one. When not in use for a long time, please take out the battery to damage the counter due to battery deterioration and leakage. After taking out the battery, press the count/pause key (PAUSE) to make the screen display disappear to turn off the internal auxiliary battery of the counter.