aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ºê·£µå À̸§: HMTX
- ±Ù¿ø: CN (Á¤Ç°)
- ÀÌ·Ð: ¿Âµµ ¼¾¼
- ÃÖ´ë ÃøÁ¤ ¿Âµµ: 120 ¡Æ ¹× À§ÀÇ
- ´ëÇü È°ÀÚ: DIGITAL
- ÀÛdz: ÀÓº£µðµå
- »ç¿ë¹ý: »ê¾÷
- ¸ðµ¨ ¹øÈ£: PT1000
- Èû À¯Çü: ¾øÀ½
- µð½ºÇ÷¹ÀÌ Å©±â: 1.9 ÀÎÄ¡ ¹× ¹Ø¿¡
- Unit Type: piece
M-series PRTDs are designed for large volume applications where long term stability,interchangeability andaccuracy over a large temperature range are vital. Typical applications are Automotive, White goods, HVAC,Energy management, Medical and Industrial equipment.
Nominal Resistance R0 | Tolerance DIN EN 60751 1996-07 | Tolerance DIN EN 60751 2009-05 |
100 Ohm at 0° | Class C | F 0.1 |
Class A | F 0.15 |
Class B | F 0.3 |
Class 2B | F 0.5 |
1000 Ohm at 0° | Class C | F 0.1 |
Class A | F 0.15 |
Class B | F 0.3 |
Class 2B | F 0.5 |
The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body.
Temperature range: 70° to +500° (continuous operation)(temporary use to 550°possible)
Tolerance Class B/D: -70° to +500°
Tolerance Class A: -50° to +300°
Tolerance Class C: 0° to +150°
(Temperature range: -70~600°-----Buy here -70~850°------Buy here -196~150°-----Buy here )
Temperature coefficient: TC = 3850 ppm/K
Leads: Pt clad Ni- wire
Recommended connection technology:
Welding, Crimping and Brazing
Lead lengths (L): A/B/C:10mm ±1mm
2B:5mm ± 0.5mm
Long-term stability: Max. R0 drift 0.04% after 1000h at 500°
Vibration resistance: At least 40g acceleration at 10 to 2000 Hz, depends on installation
Shock resistance: At least 100g acceleration with 8ms half sine wave, depends on installation
Environmental conditions: Unhoused for dry environments only
Insulation resistance: £¾100 MΩ at 20°; £¾2 MΩ at 500°
Self heating: 0.6 K/mW at 0°
Response time: Water current (v= 0.4m/s): t0.5 = 0.04s
t0.9 = 0.12s
Air stream (v= 2m/s): t0.5 = 2.2s
t0.9 = 7.0s
Measuring current: 100Ω: 0.3 to 1.0 mA
1000Ω: 0.1 to 0.3 mA (self heating has to be considered)
Note Other tolerances, values of resistance and wirelengths are available on request.
PT500B-series PRTDs are designed for large volume applications where long term stability, interchangeability andaccuracy over a large temperature range are vital. Typical applications are Automotive, White goods, HVAC,Energy management, Medical and Industrial equipment.
Nominal Resistance R0 | Tolerance DIN EN 60751 1996-07 | Tolerance DIN EN 60751 2009-05 |
500 Ohm at 0° | Class B | F 0.3 |
The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body.
Temperature range: 70° to +500° (continuous operation)(temporary use to 550°possible)
Tolerance Class B: -70° to +500°
Temperature coefficient: TC = 3850 ppm/K
Leads: Pt clad Ni- wire
Recommended connection technology:
Welding, Crimping and Brazing
Lead lengths (L): 10mm ±1mm
Long-term stability: Max. R0 drift 0.04% after 1000h at 500°
Vibration resistance: At least 40g acceleration at 10 to 2000 Hz, depends on installation
Shock resistance: At least 100g acceleration with 8ms half sine wave, depends on installation
Environmental conditions: Unhoused for dry environments only
Insulation resistance: £¾100 MΩ at 20°; £¾2 MΩ at 500°
Self heating: 0.4 K/mW at 0°
Response time: Water current (v= 0.4m/s): t0.5 = 0.05s
t0.9 = 0.15s
Air stream (v= 2m/s): t0.5 = 3.0s
t0.9 = 10.0s
Measuring current: 500Ω: 0.1 to 0.7 mA