STC-3018 STC 3018 LED Digital Temperature Controller Thermostat Thermoregulator Incubator DC 12V 24V AC 110V 220V STC3018
STC-3018
Function Description£º
Power supply: 110-220VAC plusmn 10%, 50/60Hz (or DC12V / DC24V)
Measuring temperature range: -55 deg C ~ +120 deg C
Resolution: 0.1
Accuracy: plusmn1 degC
Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
Sensor h type: imported NTC sensor, line length 1 meter
Housing material: gray ABS flame retardant plastic shell
Net weight £º120g
gross weight:140g
P0; working mode
This setting is mainly to set this value when the thermostat is used for the first time. If it is used for heating and heating, it should be set to H, and if it is used for cooling and cooling, it should be set to C.
P1; Hysteresis setting
The hysteresis is the difference required to work again after the thermostat reaches the set temperature and stops. For example, if we set the heating mode and the temperature is 37-40 degrees, then the hysteresis is 3
P2; high temperature alarm value
When the temperature reaches the set value, there will be an alarm action and stop working
P3; low temperature alarm value
When the temperature is lower than the set value, there will be an alarm action and stop working
P4; temperature correction
These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, you can use these functions to correct the value. The value of the correct value = the measured value + the corrected value. For example, the measured temperature is 25.6 degrees and the actual temperature is 25.8 degrees. Set to 0.2 then the final temperature is 25.6+0.2=25.8
P5; delay start
This function is generally used for compressor refrigeration. If you buy some thermostats for refrigerators and freezers, then this value must be set. Generally, the setting value is 3-6 minutes according to the back pressure of the compressor.
P6; C/F conversion
If you need to change the display to F value, change the unit to F, and the unit display light is on. If you need to change the display to C value, change the unit to C, and the unit display light is off. If you want to switch quickly, exit the display, press and hold Press the key for 3 seconds to quickly change the unit
![](https://ae01.alicdn.com/kf/S729fdd46e0c1404f82e2b6a7a0df08f7e.png)