¼³¸í:
Door sensor is an intelligent security equipment that can transmit through Z-Wave network and radio waves. In the Z- Wave network communications, door sensor can be connected to any Z-Wave gateway. Door sensor can send messages to Z-Wave gateway, then realize association with other devices. Different countries or areas, the radio frequency is different.
°¢ µµ¾î ¼¾¼¿¡´Â °íÀ¯ ÇÑ ID Äڵ尡 ÀÖ½À´Ï´Ù. ¿ì¸®°¡ gateway ¿þÀÌ¿¡¼ ¹® °¨Áö±â¸¦ Ãß°¡Çϰųª Á¦°ÅÇÒ ¶§, ´Ù¸¸ gateway ¿þÀÌÀÇ Z ÆÄ ³×Æ®¿öÅ© ¹üÀ§¿¡¼ ±×°ÍÀ» µÎ½Ê½Ã¿À. ±×·± ´ÙÀ½ ÀåÄ¡ ID Äڵ带 ÅëÇØ µµ¾î ¼¾¼¸¦ ½±°Ô ãÀ» ¼ö ÀÖ½À´Ï´Ù. Z- Wave gateway ¿þÀÌ¿ÍÀÇ Åë½Å¿¡¼ µµ¾î ¼¾¼´Â Z- Wave gateway ¿þÀÌ¿¡ ¸Þ½ÃÁö¸¦ º¸³¾ ¼ö ÀÖÁö¸¸ ¸Þ½ÃÁö¸¦ ¹ÞÀ» ¼ö ¾ø½À´Ï´Ù. °æº¸°¡ ¹æ¾Æ¼è¸¦ ´ç±æ ¶§, ¹® °¨Áö±â´Â ÃâÀÔ±¸¿¡ ¸Þ½ÃÁö¸¦ º¸³¾ °ÍÀÔ´Ï´Ù, ±× ÈÄ¿¡ Z ÆÄ ÃâÀÔ±¸´Â ¹® °¨Áö±âÀÇ ÇöÀç »óŸ¦ Ç¥½ÃÇÒ °ÍÀÔ´Ï´Ù. µ¿½Ã¿¡, ¹® °¨Áö±â´Â Z ÆÄ gateway ¿þÀ̸¦ ÅëÇؼ ´Ù¸¥ ÀåÄ¡¿Í Çùȸ¸¦ ±ú´ÞÀ» ¼ö ÀÖ½À´Ï´Ù. ¹® °¨Áö±â´Â °ÇÀüÁö¿¡ ÀÇÇØ, ÀÛÀº ¸ö°ú ´õºÒ¾î °ÈµÇ°í, ⠶Ǵ ¹®¿¡ ½±°Ô ¼³Ä¡µÉ ¼ö ÀÖ½À´Ï´Ù. ¹® ¶Ç´Â âÀÌ ¿¸®¸é µµ¾î ¼¾¼°¡ Æ®¸®°ÅµÇ°í ´Ù¸¥ ÀåÄ¡¿Í ¿¬°áµÇ¾î ¾ÈÀü º¸È£ÀÇ ¸ñÇ¥¸¦ ½ÇÇöÇÕ´Ï´Ù.
The status of LED
1.When door sensor is triggered, LED lights would flash red color1time.
2.When door sensor is installed with battery, LED lights would flashredcolor5times.
3.Add or remove door sensor from Z-Wave network by quickly pressing the button 3 times,then LED lights would flash red color
5times.
4.Press and hold the code button for 10-15s, then door sensor would be restored to factory default settings. Meanwhile, LED lightswouldflashredcolor5timesonandoffalternately.
5.Underthenormalstate,LEDlightswouldkeep¡°off¡°state.
Z-Wave ³×Æ®¿öÅ©¿¡ DoorSensor Ãß°¡
Door sensor can be included to Z-Wave network by pressing the code button.
1)Disassemble the main body of door sensor by pressing the disassemble button, then install battery. After making it poweredon,pleasedonotoperateitwithin20s.
2)PlacedoorsensorwithinZ-Wavenetworkrangeofgateway.
3) Set Z-Wave gateway into inclusion mode (Refer to gateway usermanual)
4)Press the code button in door sensor three times continuously, then door sensor will enter inclusion mode. Meanwhile, LED light would flash red color five times on and off alternately.
ÁÖ: ¹® °¨Áö±â´Â °ÇÀüÁö¿¡ ÀÇÇØ °ÈµÇ°í, Æø¹ßÀ» ÇÇÇϱâ À§ÇÏ¿© Á¤È®ÇÑ ¹æ¹ý¿¡ ÀÖ´Â °ÇÀüÁö¸¦ ÀÌ¿ëÇϽʽÿÀ.
5) Door sensor will be detected and included in the Z-Wave network.
6)Waitforgatewaytoconfigurethesensor.
Remove Door Senor from Z-Wave Network
1)Makesuredoorsensorispoweredon.
2) Set Z-Wave gateway into exclusion mode (Refer to gateway user manual)
3)Press the code button in door sensor three times continuously, then door sensor will enter exclusion mode. Meanwhile, LED light would flash red color five times on and off alternately.
4) Wait for gateway to remove the sensor.
°øÀå ±âº» ¼³Á¤À¸·Î µµ¾î ¼¾¼ º¹¿ø
Àç¼³Á¤ ÀýÂ÷´Â Z-wave ³×Æ®¿öÅ© ¶Ç´Â Z-Wave gateway ¿þÀÌÀÇ ¸ðµç Á¤º¸¸¦ »èÁ¦ÇÏ°í µµ¾î ¼¾¼¸¦ °øÀå ±âº» ¼³Á¤À¸·Î º¹¿øÇÕ´Ï´Ù.
1. ¹® °¨Áö±â º»Ã¼ÀÇ µ¤°³¸¦ Á¦°ÅÇϽʽÿÀ.
2. ¼¾¼°¡ ±¸µ¿µÇ´ÂÁö È®ÀÎÇϽʽÿÀ.
3. 10-15 ÃÊ µ¿¾È ¸®¼Â ¹öÆ°À» ´©¸£°í ´©¸¥ ´ÙÀ½ LED Á¶¸íÀº ºÓÀº »öÀ» 5 ¹ø ÄÑ°í ²¨Áú °ÍÀÔ´Ï´Ù.
4. ´ÜÃ߸¦ Ç®¾î ³õÀ¸½Ê½Ã¿À.
NOTE:
During the process of resetting, please make sure door sensor is powered on all the time.
Associations
(Çùȸ ¸í·É Ŭ·¡½º ¹öÀü 2)
ÀÌ ¼¾¼´Â 4 Çùȸ ±×·ìÀ» Áö¿øÇÕ´Ï´Ù. °¢ ±×·ìÀº Áö¿øµÉ ¼ö ÀÖ½À´Ï´Ùassociate5devicesmax.
ÀÌ°ÍÀº È¿°ú ¶§ Æ®¸®°Å ¸ðµç ÀåÄ¡´Â °ü·ÃµÈ ¹Þ°ÔµË´Ï´Ù °ü·Ã º¸°í¼. Çùȸ¸¦ ÅëÇØ, ¹® °¨Áö±â´Â ´Ù¸¥ Z ÆÄ ³×Æ®¿öÅ© ÀåÄ¡, e.g.aalarmdevice,wallplug,lampetc. ¸¦ ÅëÁ¦ÇÒ ¼ö ÀÖ½À´Ï´Ù.
GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) status ? Open/Close. It enables the sensor to send reports and readings to Z-Wave Gateway wheneverthesensoristriggered.ThisGroupSupport: NOTIFICATION_REPORT
BATTERY_REPORT SENSOR_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION
±×·ì 2 Çã¿ëÇÕ´Ï´Ù Àü¼Û Á¦¾î ¸í·ÉÀ» °ü·ÃµÈ ÀåÄ¡ ¸±·¹ÀÌ ¸ðµâ, Á¶¸í µî. ÀÌ Çùȸ ±×·ì ±¸¼ºµÇ¾î ÅëÇØ °í±Þ ¸Å°³ 1
2.ThisGroupSupport:BASIC_SET.
GROUP 3 allows Sending Notification to associated devices in thisgroup.ThisGroupSupport:NOTIFICATION_REPORT
±×·ì 4´Â º¸³»±â ¾Ë¸² °ü·ÃµÈ ÀåÄ¡ thisgroup.ThisGroupSupport:SENSOR_BINARY_REPORT
Advanced Configuration
1. ¿ÀÇÁ Áö¿¬ ±¸¼º
This configuration parameter can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF command immediately and 65535 means
65535secondsofdelay. Function:On/OffDuration. ParameterNumber:1. ParameterSize:2Byte
AvailableSettings:0-65535(inseconds,each1s).
DefaultSetting:0(s)
2.BasicSetLevel
Basic Set Command will be sent where contains a value when the door/window is opened or closed, Z-Wave controller or Z- Wave gateway will take it for consideration; for instance, if a lamp module receives the Basic Set Command of which value is decisiveastohowbrightofdimleveloflampmoduleshallbe. Function:BasicSet
ParameterNumber:2
ParameterSize:1Byte
Available Settings:0, 1 - 99 or 255.0 ? OFF, Alarm cancelling or turning a device off;1 - 99 or 255 ? ON (Binary Switch Device)
;DimLevel(MultilevelSwitchDevice)
DefaultSetting:255
NotificationCommandClass ÀÏ´Ü °¨Áö±â°¡ ¼¾¼ÀÇ ÀÚ¼®À» °¨ÁöÇϸé ħÀÔ À̺¥Æ®°¡ ÀÖÀ½À» ¾Ë¸®´Â ¶óÀÌÇÁ ¶óÀÎÀÇ ³ëµå¿¡ ´ëÇÑ REPORT _ º¸°íÇÕ´Ï´Ù. ÀÚ¼®ÀÌ ´ÝÈ÷¸é nodes inlifeline¿¡ nodes inlifeline·Î NOTIFICATION_REPORT ¹× SENSOR_BINARY_REPORT °¡ ´Ù½Ã º¸³»Áý´Ï´Ù.
Z ÆÄ 300 ½Ã¸®Áî¿¡ °íºÐ°íºÐÇÑ, °Å±â ¶ÇÇÑ ÀÌÁøÀ» ±ú´Ý½À´Ï´Ù
¸í¼¼:
Àü¿ø: CR2-3Vx1
Standbycurrent:1uA
Batterylife:1 ³â
¹æ»ç¼± ÇÁ·ÎÅäÄÝ: Z ÆÄ
°íÁÖÆÄ: 868.4MHzEU;908.4MHzUS;
921.4MHzANZ;869.2MHzRU
ȣȯ with300 seriesand 500 ½Ã¸®Áî
Wirelessdistance: >60m ¿Á¿Ü,> 30m ½Ç³»
Operationtemperature:0-40 ¡É
Storagetemperature:0-60 ¡É
±â¼ú Á¤º¸
¹® ¶Ç´Â â¿¡ ¼³Ä¡ÇÏ´Â
¹èÅ͸® Àü¿ø
³ª»ç ¶Ç´Â ½ºÆ¼Ä¿·Î ½±°Ô ¼³Ä¡ÇÏ´Â
Gateway ¿þÀ̸¦ ÅëÇØ ´Ù¸¥ ÀåÄ¡¿Í ¿¬°á
¾î¶² Z ÆÄ ³×Æ®¿öÅ©µçÁö¿Í ȣȯÀÌ µÇ´Â